GDE-A2200 Dust Collector – High-Performance
GDE-A2200 adalah dust collector seri GDE dari Apiste, dirancang sebagai alat high-performance untuk menyaring debu dan asap industri (welding fumes) secara efisien. Fitur utama mencakup motor blower 2.2 kW, variasi aliran udara 15/30/35 m³/min, kontrol frekuensi 20-60 Hz, dan sistem pembersihan filter otomatis dengan metode Green Pulse.
Ideal untuk lingkungan manufaktur, bengkel las, dan industri berat yang memerlukan sirkulasi udara bersih dan proteksi pekerja serta peralatan.
Spesifikasi GDE-A2200
| Specifications | Standard model |
|---|---|
| Fan motor(kW) | 2.2 |
| Air flow(m3/min) | 15/30/35 |
| Fan static pressure(kPa) | 3.09/2.86/2.60 |
| External static pressure(kPa) | 2.91/2.16/1.67 |
| Frequency adjustment range(Hz) | 20~60 |
| Operating temperature(℃) | 40 or less (No condensation) |
| Suction gas temperature(℃) | 40 or less (No condensation) |
| Clearing method | Green pulse method |
| Used compressed air pressure(MPa) | 0.5 |
| Standard air consumption(L/min [N.T.P]) | 25 |
| External dimensions(mm) | H1698×W770×D770 |
| Weight(kg) | 260 |
| Suction opening dimensions(φmm) | 198 |
| Coating color | Coating color main unit: JPMA N-75 Panels: JPMA N-35 |
| Rated voltage(V) | Three-phase AC200V (50Hz/60Hz)or 220V (60Hz) |
| Power supply wire gauge | □2 |
| Recommended breaker amperage(A) | 30 |
| Max. input current(A) * | 11.0 |
| Max. Power consumption(kW) * | 2.8 |
| Component / Fan | Turbo fan |
| Component / Motor | IE3 Vertical fl ange motor |
| Component / Main filter Area(m2) | 36 |
| Component / Ultra-fine filter ・ Count (Unit) | 6 |
| Component / Integrated pilot valve (Unit) | 2 |
| Component / Dust box ・ capacity (L×Unit) | 17×2(resin) |
| Component / Caster (φmm×Unit) | 75×4 |
| Display type | Touch-panel |
| Control output / Alarm output | Arbeit contact Non-voltage (Voltage:DC30V/AC220V or lessMaximum load:2A or less (Resistive load) /80VA(Inductive load)) |
| Control output / Caution output | Arbeit contact Non-voltage (Voltage:DC30V/AC220V or lessMaximum load:2A or less (Resistive load) /80VA(Inductive load)) |
| Control output / Operation output | Arbeit contact Non-voltage (Voltage:DC30V/AC220V or lessMaximum load:2A or less (Resistive load) /80VA(Inductive load)) |
| Control input / Operation, stop input | Non-voltage input |
| Control input / Pulse disabled | Non-voltage input |
| Control input / Pulse running | Non-voltage input |
| Noise(dB[A]) | 67±2 |